 DR-45
Input Parameter
Series
New Industrial Supplies!!
Conditions Min. 85 120 47 Typ. Max. 264 370 63 Units VAC VDC Hz A 1.0 Min. 4.75 10.8 13.5 21.6 1.0 1.0 800 60 100 100 200 240 480 150 6.75 16.2 20.25 32.4 135 0.03 100 Typ. Max. Typ. 1.0 Max. 5.5 13.2 16.5 26.4 mA Units % VDC % % mSec mSec mSec mV Pk-Pk % VDC C %/C kHz Units VAC M
Low Cost, Industrial 45W, DIN Rail Mount AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
* 45W Output Power Input Frequency Range * DIN Rail Mountable * Universal AC Input Inrush Current * UL 508 Approved Leakage Current * Safety Approved Output * 5, 12, 15 & 24 VDC Outputs Parameter * Cond./Rad. EMI Class B Output Voltage Tolerance * >364 kH MTBF * LOW COST!
Line Regulation Load Regulation Set Up Time Rise Time Hold Time Ripple & Noise (Note 2) Output Power Protection
Input Voltage Range
230 VAC, Cold Start 115 VAC, Cold Start 240 VAC Conditions Note 1 5 VDC Output 12 VDC Output 15 VDC Output 48 VDC Output
56 28
Voltage Adjustment Range
Over Voltage Protection (Note 4) Over Temperature Protection Temperature Coefficient Switching Frequency General Parameter
Iout = 10% to 100% 230 VAC, Full Load At Full Load 230 VAC, Full Load 5 VDC Output 12 VDC Output 15 VDC Output 24 VDC Output Note 3 105 5 VDC Output 5.75 12 VDC Output 13.8 15 VDC Output 17.25 24 VDC Output 27.6 Note 5 0C to 50C Fixed Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Conditions Min. 3,000 1,500 500 100
RoHS Compliant
MicroPower Direct
232 Tosca Drive Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Isolation Voltage Isolation Resistance (Note 6) Environmental Parameter Operating Temperature Range Storage Temperature Range Operating Humidity Storage Humidity Vibration Physical Case Size Case Material Connection Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals EMI Compliance Harmonic Current Compliance EMS Immunity Compliance
Min. Typ. Max. Units -10 +25 +50 C -20 +85 C RH, Non-condensing 20 90 % RH, Non-condensing 10 95 % 10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Ambient 3.66 x 3.05 x 2.64 Inches (93.0 x 78.0 x 67.0 mm) Plastic (UL94-V0) Screw Terminal 11 Oz (0.31 kg)
Min. Typ. Max. Units 364.6 kHours UL 508, UL 60950, EN 60950-1 UL, cUL, TUV Compliance to EN55011, EN55022 (CISPR22) Class B Compliance to EN6100-3-2,-3 EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Conditions MIL HDBK 217F, 25C, Gnd Benign
Model Selection Guide
Model Number DR-45-05 DR-45-12 DR-45-15 DR-45-24 Rated Power (W) 25 42 42 48 Input Voltage (VAC) Range 85 - 264 85 - 264 85 - 264 85 - 264 Current (A) 115 VAC 1.5 1.5 1.5 1.5 230 VAC 0.75 0.75 0.75 0.75 Voltage (VDC) 5 12 15 24 Output Current (A) Max) 5.0 3.5 2.8 2.0 Current (A) Range 0 ~ 5.0 0 ~ 3.5 0 ~ 2.8 0 ~ 2.0 Efficiency (%, Typ) 72 77 77 80 Fuse Rating Slow-Blow (A) 5.0 5.0 5.0 5.0
Notes: 1. Output voltage tolerance includes set-up tolerance, line regulation and load regulation. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth. Connection to the unit under test is made with a 12 inch length of "twisted pair" wires terminated with a set of 1.0 F & 4.7 F capacitors connected in parallel. 3. Overload protection is foldback current limiting. The unit recovers automatically when the fault is removed. 4. Over voltage protection is a shut down type. The power to the unit must be manually reset to recover. 5. Over temperature protection shuts down the output. The unit recovers automatically when the temperature goes down. The thermal detector is mounted on the heat sink of the power semiconductor. 6. Isolation resistance is given for Input/Output; Input/FG and Output/FG. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the DR-45 series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Mechanical Dimensions
Terminal Connections
Pin 1 2 3 4,5 Function AC/Live (DC-) AC/Neutral (DC+) Frame Ground (FG) DC Output (-V) Pin 6,7 8 9 Function DC Output (+V) LED +VAdj Mechanical Notes:
* All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
Static Characteristics (24 Vout)
Derating Curve - Output Power vs Ambient Temp.
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
*
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of DR-45-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X